文献
J-GLOBAL ID:201802242004698498
整理番号:18A0844128
人工関節材料としての超低摩耗ポリエチレンの生体適合性,トライボロジー特性および摩耗粉特性に関する研究【JST・京大機械翻訳】
Study on biocompatibility, tribological property and wear debris characterization of ultra-low-wear polyethylene as artificial joint materials
著者 (7件):
Bian Yan-Yan
(Department of Orthopedics, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China)
,
Zhou Lei
(Department of Orthopedics, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China)
,
Zhou Gang
(Key Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Sciences and Medical Engineering, Beihang University, China)
,
Jin Zhong-Min
(School of Mechanical Engineering, Xian Jiaotong University, China and School of Mechanical Engineering, University of Leeds, UK)
,
Xin Shi-Xuan
(PetroChina Petrochemical Research Institute, PetroChina Synthetic Resin key Laboratory, Beijing 100195, China)
,
Hua Zi-Kai
(School of Mechatronics Engineering and Automation, Shanghai University, China)
,
Weng Xi-Sheng
(Department of Orthopedics, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing 100730, China)
資料名:
Journal of the Mechanical Behavior of Biomedical Materials
(Journal of the Mechanical Behavior of Biomedical Materials)
巻:
82
ページ:
87-94
発行年:
2018年
JST資料番号:
W2351A
ISSN:
1751-6161
資料種別:
逐次刊行物 (A)
記事区分:
原著論文
発行国:
オランダ (NLD)
言語:
英語 (EN)