文献
J-GLOBAL ID:201802284635866264
整理番号:18A0794947
自動化ラボインシリンジ法を用いた鉛のナノモル濃度の定量のための直接浸漬単一液滴ミクロ抽出と液滴内撹はんミクロ抽出【JST・京大機械翻訳】
Direct-immersion single-drop microextraction and in-drop stirring microextraction for the determination of nanomolar concentrations of lead using automated Lab-In-Syringe technique
著者 (5件):
Sramkova Ivana H.
(Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Kralove, Charles University, Akademika Heyrovskeho 1203, 500 05 Hradec Kralove, Czech Republic)
,
Horstkotte Burkhard
(Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Kralove, Charles University, Akademika Heyrovskeho 1203, 500 05 Hradec Kralove, Czech Republic)
,
Fikarova Katerina
(Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Kralove, Charles University, Akademika Heyrovskeho 1203, 500 05 Hradec Kralove, Czech Republic)
,
Sklenarova Hana
(Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Kralove, Charles University, Akademika Heyrovskeho 1203, 500 05 Hradec Kralove, Czech Republic)
,
Solich Petr
(Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Kralove, Charles University, Akademika Heyrovskeho 1203, 500 05 Hradec Kralove, Czech Republic)
資料名:
Talanta
(Talanta)
巻:
184
ページ:
162-172
発行年:
2018年
JST資料番号:
E0324A
ISSN:
0039-9140
資料種別:
逐次刊行物 (A)
記事区分:
原著論文
発行国:
オランダ (NLD)
言語:
英語 (EN)