Rchr
J-GLOBAL ID:202101002784080729   Update date: Dec. 28, 2023

Sakai Noriyuki

サカイ ノリユキ | Sakai Noriyuki
Affiliation and department:
Job title: Radiological Technologist
Research field  (1): Radiology
Research keywords  (11): 放射線技術科学 ,  画像診断 ,  画質評価 ,  X線透視 ,  被ばく低減 ,  医療被ばく ,  職業被ばく ,  CT ,  逐次近似画像再構成法 ,  フレームレート変換技術 ,  放射線治療技術
Research theme for competitive and other funds  (1):
  • 2023 - 2026 X線透視ガイド下手技における患者・術者の放射線性障害の低減方法の構築
Papers (6):
  • Mitsuhiro Kimura, Hidetake Yabuuchi, Hiroshi Narita, Yoichi Kurihara, Kiyoshi Hisada, Noriyuki Sakai, Kazuya Nagatomo, Ryoji Mikayama, Masafumi Masaki, Hiroshi Kimura. Intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) of the major salivary glands: an assessment of the optimal number and combination of b-values. Polish journal of radiology. 2022. 87. e246-e256
  • Noriyuki Sakai, Katsuyuki Tabei, Jiro Sato, Toshikazu Imae, Yuichi Suzuki, Shigeharu Takenaka, Keiichi Yano, Osamu Abe. Radiation dose reduction with frame rate conversion in X-ray fluoroscopic imaging systems with flat panel detector: basic study and clinical retrospective analysis. European Radiology. 2019. 29. 2. 985-992
  • Tsukasa Kojima, Hidetake Yabuuchi, Hiroshi Narita, Seiji Kumazawa, Yuzo Yamasaki, Yuki Yano, Noriyuki Sakai, Yoichi Kurihara, Kiyoshi Hisada, Masafumi Masaki, et al. Efficacy of the radial acquisition regime (RADAR) for acquiring head and neck MR images. The British Journal of Radiology. 2016. 89. 1067. 20160007-20160007
  • Kazuya Nagatomo, Hidetake Yabuuchi, Yuzo Yamasaki, Hiroshi Narita, Seiji Kumazawa, Tsukasa Kojima, Noriyuki Sakai, Masahumi Masaki, Hiroshi Kimura. Efficacy of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) for shoulder magnetic resonance (MR) imaging. European Journal of Radiology. 2016. 85. 10. 1735-1743
  • Noriyuki Sakai, Hidetake Yabuuchi, Masatoshi Kondo, Tsukasa Kojima, Kazuya Nagatomo, Satoshi Kawanami, Takeshi Kamitani, Masato Yonezawa, Michinobu Nagao, Hiroshi Honda. Volumetric measurement of artificial pure ground-glass nodules at low-dose CT: Comparisons between hybrid iterative reconstruction and filtered back projection. European Journal of Radiology. 2015. 84. 12. 2654-2662
more...
Books (1):
  • 映像情報Medical 2017年2月号 「特集1:フラットパネルディテクタ2017」 p.6-10 FPD搭載X線透視診断装置におけるフレームレート変換技術の基礎的評価と使用経験
    産業開発機構 2017 ISBN:4860282590
Lectures and oral presentations  (27):
  • Radiation dose reduction of newborns without anti-scatter grids in X-ray fluoroscopic imaging systems with flat panel detectors: a newborn whole body phantom study of dosimetry and visual assessment
    (RSNA (Radiological Society of North America) 109th Scientific Assembly and Annual Meeting)
  • 強度変調放射線回転照射法を適用した全身照射における位置誤差に関する検討
    (第51回日本放射線技術学会秋季学術大会)
  • FPD搭載X線透視診断装置における逐次近似再構成法の有無による被ばく線量の測定:新生児全身ファントムによる比較研究
    (日本放射線技術学会 第77回東京支部 春期学術大会)
  • FPD搭載X線透視診断装置におけるグリッド有無による被ばく線量の測定:新生児全身ファントムによる比較研究
    (日本放射線技術学会 第77回東京支部 春期学術大会)
  • 深層学習により画質改善したCBCT画像を用いた積算線量分布の構築
    (日本放射線腫瘍学会第35回学術大会 2022)
more...
Education (2):
  • 2013 - 2015 九州大学大学院 医学系学府 保健学専攻 医用量子線科学分野
  • 2009 - 2013 Kyushu University
Work history (1):
  • 2015/04 - 現在 東京大学医学部附属病院 放射線部 診療放射線技師
Association Membership(s) (2):
Japanese Society of Radiological Technology ,  Japan Society of Medical Physics
※ Researcher’s information displayed in J-GLOBAL is based on the information registered in researchmap. For details, see here.

Return to Previous Page