Calibration wind tunnel

校正用低乱風洞
Owning Organization:
Contact: TOKUGAWA Naoko
Resource classification: Experience equipment, Facilities, etc
Overview:
System: Single path circulation Göttingen type
Wind speed: 1m/s - 65m/s
Measurement part: H 0.65m, W 0.55m, L 1.5m
Blower power: 37kW
Air flow characteristics: Total turbulence 0.05%
0.022% (at 30m/s) of vortical component
User environment and conditions:
None
User procedures and method:
[Procedure for Use]
Refer in detail to Business Squad, Planning Room.
[Charge for Use]
According to the calculation standard of acceptance
research
expenses appointed by the Japan Aerospace Exploration
Agency
[Restriction for use]
Uses by a person not belonging to national
administration organs are limited to a case
approved to be especially necessary for improvement
of aeronautical technology and space technology.