Art
J-GLOBAL ID:201502204918682299   Reference number:15A0609292

Experimental Study on Return Loss of Exponential Tapered Line Type Conical Monopole Antenna

指数テーパ線路型コニカルモノポールアンテナのリターンロスに関する実験的検討
Author (3):
Material:
Volume: 135  Issue:Page: 271-275 (J-STAGE)  Publication year: 2015 
JST Material Number: S0808A  ISSN: 0385-4205  Document type: Article
Article type: 原著論文  Country of issue: Japan (JPN)  Language: JAPANESE (JA)
Abstract/Point:
Abstract/Point
Japanese summary of the article(about several hundred characters).
All summary is available on JDreamIII(charged).
On J-GLOBAL, this item will be available after more than half a year after the record posted. In addtion, medical articles require to login to MyJ-GLOBAL.
Exponential tapered line type ...
   To see more with JDream III (charged).   {{ this.onShowAbsJLink("http://jdream3.com/lp/jglobal/index.html?docNo=15A0609292&from=J-GLOBAL&jstjournalNo=S0808A") }}
Thesaurus term:
Thesaurus term/Semi thesaurus term
Keywords indexed to the article.
All keywords is available on JDreamIII(charged).
On J-GLOBAL, this item will be available after more than half a year after the record posted. In addtion, medical articles require to login to MyJ-GLOBAL.

Semi thesaurus term:
Thesaurus term/Semi thesaurus term
Keywords indexed to the article.
All keywords is available on JDreamIII(charged).
On J-GLOBAL, this item will be available after more than half a year after the record posted. In addtion, medical articles require to login to MyJ-GLOBAL.

JST classification (2):
JST classification
Category name(code) classified by JST.
Electrostatic equipment  ,  Antennas 
Reference (13):
  • (1) P. F. Wilson and M. T. Ma : “Field Radiated by Electrostatic Discharge”, IEEE Trans. Electromagn. Compat., Vol. 33, No. 1, pp. 10-18 (1991-2)
  • (2) M. Masugi, K. Murakawa, N. Kuwabara, and F. Amemia : “Measurement and Analysis of Electromagnetic Pulsees Radiated from a Charged Copper Pipe”, T. IEE Japan, Vol. 112-A, No. 12, pp. 1020-1026 (1992) (in Japanese)
  • 馬杉正男・村川一雄・桑原伸夫・雨宮不二雄:「帯電銅パイプから放射される電磁パルスの測定と解析」, 電学論A, Vol. 112, No. 12, pp. 1020-1026 (1992)
  • (3) O. Fujiwara and T. Hori : “Level Estimation of Transient Electromagnetic Fields Caused by Spark Discharge between Charged Metal Spheres”, T. IEE Japan, Vol. 118-C, No. 1, pp. 9-14 (1998) (in Japanese)
  • 藤原 修・堀 武雄:「帯電金属球間の火花放電による発生電磁界のレベル推定」, 電学論C, Vol. 118, No. 1, pp. 9-14 (1998)
more...
Terms in the title (5):
Terms in the title
Keywords automatically extracted from the title.

Return to Previous Page