Art
J-GLOBAL ID:201502297294379950   Reference number:15A0326900

Three-unit reinforced polyetheretherketone composite FDPs: Influence of fabrication method on load-bearing capacity and failure types

3ユニット補強ポリエーテルエーテルケトンコンポジットFDP:製作法が耐荷重能力に及ぼす影響と失敗型
Author (6):
Material:
Volume: 34  Issue:Page: 7-12 (J-STAGE)  Publication year: 2015 
JST Material Number: Y0283A  ISSN: 0287-4547  Document type: Article
Article type: 原著論文  Country of issue: Japan (JPN)  Language: ENGLISH (EN)
Thesaurus term:
Thesaurus term/Semi thesaurus term
Keywords indexed to the article.
All keywords is available on JDreamIII(charged).
On J-GLOBAL, this item will be available after more than half a year after the record posted. In addtion, medical articles require to login to MyJ-GLOBAL.
,...
Semi thesaurus term:
Thesaurus term/Semi thesaurus term
Keywords indexed to the article.
All keywords is available on JDreamIII(charged).
On J-GLOBAL, this item will be available after more than half a year after the record posted. In addtion, medical articles require to login to MyJ-GLOBAL.
,...
   To see more with JDream III (charged).   {{ this.onShowAbsJLink("http://jdream3.com/lp/jglobal/index.html?docNo=15A0326900&from=J-GLOBAL&jstjournalNo=Y0283A") }}
JST classification (1):
JST classification
Category name(code) classified by JST.
Dental prosthetic materials 
Reference (30):
  • 1) Gracis SE, Nichols JI, Chalupnik JD, Yuodelis RA. Shockabsorbing behavior of five restorative materials used on implants. Int J Prosthodont 1991; 4: 282-291.
  • 2) Magne P, Schlichting LH, Maia HP, Baratieri LN. In vitro fatigue resistance of CAD/CAM resin composite and ceramic posterior occlusal veneers. J Prosthet Dent 2010; 104: 149-157.
  • 3) Alt V, Hannig M, Wöstmann B, Balkenhol M. Fracture strength of temporary fixed partial dentures: CAD/CAM versus directly fabricated restorations. Dent Mater 2011; 27: 339-347.
  • 4) Göncü Başaran E, Ayna E, Vallittu PK, Lassila LVJ. Loadbearing capacity of handmade and computer-aided design computer-aided manufacturing-fabricated three-unit fixed dental prostheses of particulate filler composite. Acta Odontol Scand 2011; 69: 144-150.
  • 5) Stawarczyk B, Ender A, Trottmann A, Özcan M, Fischer J, Hämmerle CH. Load-bearing capacity of CAD/CAM milled polymeric three-unit fixed dental prostheses: Effect of aging regimens. Clin Oral Investig 2012; 16: 1669-1677.
more...
Terms in the title (5):
Terms in the title
Keywords automatically extracted from the title.