Art
J-GLOBAL ID:201602248065344182   Reference number:16A1305486

Influence of Surface Texture on Friction Properties of Mechanical Seals for Blood -Design Concept of Sealing Surface of Mechanical Seal for Ventricular Assist Device-

血液に対するメカニカルシールの摩擦特性における表面テクスチャーの影響-心室補助人工心臓に対するメカニカルシールのシール面の設計概念-
Author (6):
Material:
Volume: 11  Issue:Page: 366-375(J-STAGE)  Publication year: 2016 
JST Material Number: U0046A  ISSN: 1881-2198  Document type: Article
Article type: 原著論文  Country of issue: Japan (JPN)  Language: ENGLISH (EN)
Thesaurus term:
Thesaurus term/Semi thesaurus term
Keywords indexed to the article.
All keywords is available on JDreamIII(charged).
On J-GLOBAL, this item will be available after more than half a year after the record posted. In addtion, medical articles require to login to MyJ-GLOBAL.
,...
Semi thesaurus term:
Thesaurus term/Semi thesaurus term
Keywords indexed to the article.
All keywords is available on JDreamIII(charged).
On J-GLOBAL, this item will be available after more than half a year after the record posted. In addtion, medical articles require to login to MyJ-GLOBAL.
,...
   To see more with JDream III (charged).   {{ this.onShowAbsJLink("http://jdream3.com/lp/jglobal/index.html?docNo=16A1305486&from=J-GLOBAL&jstjournalNo=U0046A") }}
Author keywords (7):
JST classification (2):
JST classification
Category name(code) classified by JST.
Sealing devices  ,  Prosthesis(=artificial substitutes for body part) 
Reference (21):
  • [1] Kyo, S., Minami, T., Nishimura, T., Gojo, S. and Ono, M., “New Era for Therapeutic Strategy for Heart Failure: Destination Therapy by Left Ventricular Assist Device,” Journal of Cardiology, 59, 2, 2012, 101-109.
  • [2] Saito, S., Yamazaki, K., Nishinaka, T., Ichihara, Y., Ono, M., Kyo, S., Nishimura, T., Nakatani, T., Toda, K., Sawa, Y., Tominaga, R., Tanoue, T., Saiki, Y., Matsui, Y., Takemura, T., Niinami, H. and Matsumiya, G., “Post-Approval Study of a Highly Pulsed, Low-Shear-Rate, Continuous-Flow, Left Ventricular Assist Device, EVAHEART: A Japanese Multicenter Study Using J-MACS,” The Journal of Heart and Lung Transplantation: The Official Publication of the International Society for Heart Transplantation, 33, 6, 2014, 599-608.
  • [3] Yamazaki, K., Mori, T., Tomioka, J., Litwak, P., Antaki, J. F., Tagusari, O., Koyanagi, H., Griffith, B. P. and Kormos, R. L., “The Cool Seal System: A Practical Solution to the Shaft Seal Problem and Heat Related Complications With Implantable Rotary Blood Pumps,” ASAIO Journal, 43, 5, 1997, M567-M571.
  • [4] Umezu, M., Iwasaki, K., Qian, Y., Yagi, T., Yamazaki, K., Kitano, T., Tokuno, T. and Yamazaki, S., “Is There Any Possibility That Heart Transplantation Can Be Replaced by an Artificial Heart?,” Gerontechnology, 7, 2, 2008, 228.
  • [5] Yamazaki, K., Litwak, P., Tagusari, O., Mori, T., Kono, K., Kameneva, M., Watach, M., Gordon, L., Miyagishima, M., Tomioka, J., Umezu, M., Outa, E., Antaki, J. F., Kormos, R. L., Koyanagi, H. and Griffith, B. P., “An Implantable Centrifugal Blood Pump with a Recirculating Purge System (Cool-Seal System),” Artificial Organs, 22, 6, 1998, 466-474.
more...