文献
J-GLOBAL ID:201902230243459706
整理番号:19A1364767 3.2.5 LET依存性のないゲル線量計の開発-MRI(磁気共鳴画像)を用いたフリッケゲル線量計-
3.2.5 Development of LET-independent Gel Dosimeter-MRI (magnetic resonance imaging)-based Fricke Gel Dosimeter-
- 1) Seco, J., Clasie, B. and Partridge, M., Review on the characteristics of radiation detectors for dosimetry and imaging, Phys. Med. Biol., 59, R303-R347 (2014)
- 2) Kron, T., Lehmann, J. and Greer, P. B., Dosimetry of ionising radiation in modern radiation oncology, Phys. Med. Biol., 61, R167-R205 (2016)
- 3) Hara, Y., Furukawa, T., Mizushima, K., Inaniwa, T., et al., Commissioning of full energy scanning irradiation with carbon-ion beams ranging from 55.6 to 430MeV/u at the NIRS-HIMAC, Nucl. Instrum. Methods Phys. Res. B, 406, 343-346 (2017)
- 4) Iwata, Y., Fujita, T., Fujimoto, T., Furukawa, T., et al., Development of Carbon-Ion Radiotherapy Facilities at NIRS, IEEE Trans. Appl. Supercond., 28, 1-7 (2018)
- 5) Karger, C. P., Jakel, O., Palmans, H. and Kanai, T., Dosimetry for ion beam radiotherapy, Phys. Med. Biol., 55, R193-R234 (2010)
- 6) Giordanengo, S., Manganaro, L. and Vignati, A., Review of technologies and procedures of clinical dosimetry for scanned ion beam radiotherapy, Phys. Med., 43, 79-99 (2017)
- 7) Daniel, K., Stuart, G., Hugo, P., et al., LET dependence of GafChromic films and an ion chamber in low-energy proton dosimetry, Phys. Med. Biol., 55, 417-433 (2010)
- 8) Fiorini, F., Kirby, D., Thompson, J., Green, S., et al., Under-response correction for EBT3 films in the presence of proton spread out Bragg peaks, Phys. Med., 30, 454-461 (2014)
- 9) Hara, Y., Furukawa, T., Mizushima, K., Takeshita, E., et al., Application of radiochromic film for quality assurance in the heavy-ion beam scanning irradiation system at HIMAC, Nucl. Instrum. Methods Phys. Res. B, 331, 253-256 (2014)
- 10) Debrot, E., Newall, M., Guatelli, S., Petasecca, M., et al., A silicon strip detector array for energy verification and quality assurance in heavy ion therapy, Med. Phys., 45, 953-962 (2018)
- 11) Kaiser, F. J., Bassler, N. and Jakel, O., COTS Silicon diodes as radiation detectors in proton and heavy charged particle radiotherapy 1, Radiat. Environ. Biophys., 49, 365-371 (2010)
- 12) Parisi, A., Van Hoey, O., Mégret, P. and Vanhavere, F., The influence of the dose assessment method on the LET dependence of the relative luminescence efficiency of LiF: Mg, Ti and LiF: Mg, Cu, P, Radiat. Meas., 98, 34-40 (2017)
- 13) Kim, S., Lee, S. B., Yoo, S. H., Cho, S., et al., Quenching effect, signal to noise, contrast to noise ratios on scintillator screens for proton beam dosimetry system, Jpn. J. Appl. Phys., 51(4R), 046401 (2012)
- 14) Furukawa, T., Saotome, N., Inaniwa, T., Sato, S., et al., Delivery verification using 3D dose reconstruction based on fluorescence measurement in a carbon beam scanning irradiation system, Med. Phys., 35, 2235-2242 (2008)
- 15) Fricke, H. and Hart, E. J., Chemical Dosimetry. In: Attix F. H., Roesch W. C., Tochilin E. editors. Radiation Dosimetry: Instrumentation. 167-239 1966, Academic Press, New York
- 16) Maeyama, T., Yamashita, S., Taguchi, M., Baldacchino, G., et al., Production of a fluorescence probe in ion-beam radiolysis of aqueous coumarin-3-carboxylic acid solution-2: Effects of nuclear fragmentation and its simulation with PHITS, Radiat. Phys. Chem., 80, 1352-1357 (2011)
- 17) Maeyama, T., Yamashita, S., Baldacchino, G., Taguchi, M., et al., Production of a fluorescence probe in ion-beam radiolysis of aqueous coumarin-3-carboxylic acid solution-1: Beam quality and concentration dependences, Radiat. Phys. Chem., 80, 535-539 (2011)
- 18) Baldacchino, G., Maeyama, T., Yamashita, S., Taguchi, M., et al., Determination of the time-dependent OH-yield by using fluorescent probe. Application to heavy ion irradiation, Chem. Phys. Lett., 468, 275-279 (2009)
- 19) Yamashita, S., Katsumura, Y., Lin, M. Z., Muroya, Y., et al., Water radiolysis with heavy ions of energies up to 28 GeV-2: Extension of primary yield measurements to very high LET values, Radiat. Phys. Chem., 77, 1224-1229 (2008)
- 20) Watanabe, Y., Warmington, L. and Gopishankar, N., Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications, World J. Radiol., 9, 112-125 (2017)
前のページに戻る